MEC-1000 8inch Patient Monitor
Minimum Order Quantity: 1 Piece
Type of display | LCD |
Brand | Unitech |
Model | MEC-1000 |
Parameters Measured | ECG, RESP, NIBP, Temperature, SPO2 |
Suitable For | Neonatal, Adult, Pediatric |
No of Leads in ECG | 5 |
Pulse Rate Range | 40-240 bpm |
12 Lead interpretation of ECG | Yes |
Number of leads analyzed for ECG in single time | 5 |
8 inch Six Standard parameters: ECG,RESP,NIBP,SPO2,TEMP,PR/HR
- 13 Type Arrhythmic Analysis, Multi_Lead ECG Waveforms Display in Phase, Real time S_T segment analysis, pacemaker detection Drug calculation and titratiotable;
- Efficient resistance to interference of defibrillator and electrosurgical cautery;
- SPO2 can testing for 0.1% Weak;
- RA-LL impedance Respiration;
- Trend Coexist Display;
- OxyCRG DyNamic View Display;
- Bed to Bed view Display;
- Networking capacity and nurse_calling system;
- Options of printing, IBP, VGA and EtCO2;
- UP to 4 hours working capacity of built_in rechargeable battery;
- 11.8.4" high resolution color TFT LCD display;
- Large volume of tabular and graphic trends information storage and easy to recall;
- Anti-ESU, anti- defibrillator;
- Capture dynamic waveforms.
Additional Information:
- Delivery Time: Immediately
- Packaging Details: Box
Hamilton Raphael Ventilator
Minimum Order Quantity: 1 Piece
Tidal Volume | 50 to 2000 ml |
Brand | Hamilton Medical |
Model Name/Number | Raphael Color |
Ventilation Modes | (S)CMV+, PCV+, SIMV+, PSIMV+, DuoPAP, APRV, SPONT, NIV, ASV |
Patient Age Group | Adult, Paediatric |
Intended use
The RAPHAEL ventilator is a continuous ventilator designed for ventilation of adult and pediatric patients weighing between 5 and 200 kg. The RAPHAEL ventilator is intended for use by properly trained personnel under the direct supervision of a licensed physician. The RAPHAEL ventilator is intended for use in a hospital or hospital-type facility, including use at a patient bedside or for intrafacility transport, provided compressed gas is supplied.
General operation notes
• The RAPHAEL ventilator is intended for use by properly trained personnel under the direct supervision of a licensed physician.
• Familiarize yourself with this operator’s manual before using the ventilator on a patient.
• The displays shown in this manual may not exactly match what you see on your own ventilator.
• Not all ventilator models, accessories, and features in this manual are available in all markets.
• CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.
Monitoring and alarms
• The RAPHAEL is not intended to be a comprehensive vital sign monitor for patients on life-support equipment. Patients on life-support equipment should be appropriately monitored by qualified medical personnel and suitable monitoring devices. The use of an alarm monitoring system does not give absolute assurance of warning for every form of malfunction that may occur with the ventilator.
• Do not silence the audible alarm when leaving the patient unattended. vi 610994/04
• An alternative means of ventilation shall be available whenever the ventilator is in use. If a fault is detected in the ventilator and its life-support functions are in doubt, ventilation must be started without delay with such a device (for example, a resuscitation bag), using PEEP and/or increased oxygen concentration when appropriate. The ventilator must be removed from clinical use and serviced by qualified personnel.
• In case of malfunction of the ventilator’s built-in monitoring and in order to maintain an adequate level of patient monitoring at all times, it is recommended that additional independent monitoring devices be used. The operator of the ventilator must still maintain full responsibility for proper ventilation and patient safety in all situations
Additional Information:
- Delivery Time: Immediately
- Packaging Details: Box